Technical Specification / The Fire Beam XTRA

The Fire Beam XTRA Technical Specification

A full technical specification of the Fire Beam XTRA and associated components can be seen below, answering most of the questions you may have.

Electrical Specifications:
Supply Voltage 10.2 to 30 VDC
Supply Current 3.5mA (constant current) in all operational states
Constant Current 17mA (constant current) in fast commissioning
Environmental Specifications:
Temperature -10°C to +55°C
Humidity 10 to 95% RH Non-condensing
Protection Index IP65 when suitably mounted and terminated
Mechanical Specifications:
Beam Head H:180mm x W:155mm x D:137mm - Weight 1.1kg
Controller H:185mm x W:120mm x D:62mm - Weight 0.55kg
Mid Range Kit H:293mm x W:293mm x D:5mm - Weight 0.8kg
Long Range Kit H:394mm x W:394mm x D:5mm - Weight 1.8kg
Unistrut Adaptor H:270mm x W:250mm x D:5mm - Weight 0.6Kg
(mounts the Beam Head onto Unistrut)
Optical Specifications:
Optical Wavelength 870nm
Maximum Angular Alignment ±5°
Maximum Angular Misalignment (static not auto-aligning)
Beam Head ±0.75°  /  Reflector ±2°
Operational Specifications:
Protection Range
Fire Beam XTRA As standard up to 70 metres
Mid Range Kit 70 to 140 metres
Long Range Kit 140 to 160 metres
Alarm Sensitivity Levels
25% (1.25dB) to 50% (3dB) in 1% (0.05dB) increments (default 35% (1.87dB))
Alarm Condition:
Obscuration drops to below pre-defined sensitivity level.
Time to Alarm Condition adjustable between 2 to 30 seconds in 1 second increments (default 10 seconds)
Alarm Indication:
Controller Status - FIRE
Controller Red Flashing LED
Head Red Flashing LED
Alarm Relay Change Over (CO) Contact
Rating 2A @ 30 VDC
Test / Reset Features:
Beam test function by controller
Alarm latching / auto-reset selectable (default auto-reset)
Alarm reset in latching mode by controller reset function, removing power for >5 seconds, apply 12 to 24 VDC to reset connections in Beam Head.
Fault Sensitivity Level:
90%
Fault Condition:
Obscuration drops to below the fault sensitivity level within 1 second
Power Down or Supply Voltage < 9 VDC
Commissioning modes, Pre-Alignment and Auto-Alignment
Beam turned off during Beam Maintenance
Time to Fault Condition adjustable, 2 to 60 seconds in 1 second increments (default 10 seconds)
Fault Indication:
Controller Status - FAULT
Controller Yellow Flashing LED 1 Second
Head Yellow Flashing LED 1 Second
Fault Relay Change Over (CO) Contact Rating 2A @ 30 VDC
Normal Condition:
Obscuration level is above the Alarm sensitivity level
Controller Status - NORMAL
Controller Green Flashing LED
Programmable on/off
Head Green Flashing LED
Programmable on/off
Auto-Align / Beam Contamination Compensation:
Auto-align during normal operation if obscuration drops below 90% for the duration of the align time set (doesn't affect normal operating mode)
Beam Contamination Compensation 4 hour monitoring. Compensation data available at the controller

PDF User Guides

Download Fire Beam User Guides

User guides, brochures, wiring diagrams and more can be downloaded at any time by creating a free User Zone account.

User Testimonials

Fire Beam Testimonials

The Fire Beam is helping to protect lives and property around the world. Read what our users really think of The Fire Beam in our Testimonials section.

Extend The Range

Fire Beam Range Kits

The Fire Beam Xtra covers distances up to 70 metres, but with the addition of one of our Range Kits it can cover distances up to 160 metres. View Distance Kits

Fire Beam Extras

Fire Beam Accessories & Add-Ons

Anti-fog/condensation kits, power supplies, adjustable brackets, adaptor plates and more. View Accessories

Fire Beam Xtra

Fire Beam Xtra

The Fire Beam Xtra is now our standard beam and features many new and innovative advances, pushing it further ahead as the market leader. More